Bildegalleri
22 meter bunt med kabel 1,5m3 - Kabeltec Flex-CY-J2 - GI BUD
Trygg handel med Fiks ferdig
Varen blir sendt til deg, og du har 24 timer på deg til å inspisere den før pengene overføres til selger.
Beskrivelse av varen
Ny kabel, ikke kjent hvor lang den er. sikker 20-22 meter.
Ta kontakt, så kan jeg sjekke.
GI BUD.
Used as connecting cable, as measuring, power and control cable in machine tool
manufacturing, plant engineering and on assembly lines and production lines to
meet stringent safety requirements.
Suitable for fixed installation or flexible applications with unrestricted mobility
without forced movement control and without exposure to tensile load.
Installation in dry and moist rooms; outdoor installation not permitted. These
cables with copper screening are ideally suitable for interference-free data and
signal transmission in measuring and control technology.
Good chemical resistance, largely oil resistant
fine strands of bare copper conductor
- stranding acc. to VDE 0295, class 5
- PVC core insulation black with continuous white figure imprint
- earth conductor green/yellow
- PVC inner sheath grey
- overall screen made of tinned copper wire braid
- PVC outer sheath transparent
Technische Daten: Technical Data:
Leiter Werkstoff Kupfer, blank Conductor Material Copper, bare
Leiterklasse Klasse 5 nach DIN VDE 0295, bzw. IEC 60228 Conductor class Class 5 acc. to DIN VDE 0295, or IEC 60228
Aderisolationwerkstoff PVC core insulation PVC
Aderkennung DIN VDE 0293: Schwarze Adern mit fortlaufendem
weißen Ziffernaufdruck
core identification DIN VDE 0293: black cores, white numbers
Verseilung Adern in Lagen verseilt stranding Cores twisted in layers
Außenmantelwerkstoff PVC outer sheath PVC
Mantelfarbe Transparent sheath colour Transparent
Nennspannung [V] 300 / 500 rated voltage [V] 300/500
Prüfspannung [V] 4000 testing voltage [V] 4000
Leiterwiderstand conductor resistance
Isolationswiderstand 20 MΩ x km insulation resistance 20 MΩ x km
Strombelastbarkeit DIN VDE (s. technischer Anhang) current carrying capacity DIN VDE (s. technical guidance)
kleinster Biegeradius fest [xd] 6 x d min. bending radius fixed [xd] 6 x d
kleinster Biegeradius bewegt [xd] 15 x d min. bending radius moved [xd] 15 x d
Betriebstemp. fest min/max [C] -40°C bis +80°C working temp fixed min/max [C] -40°C up to +80°C
Betriebstemp. bew. min/mac [C] -15°C bis +70°C working temp moved min/mac [C] -15°C up to +70°C
Temperatur am Leiter max. +70°C bei Betrieb,
+150°C im Kurzschlussfall
temp at conductor max. +70°C in operation,
+150°C in case of short-circuit
Brandverhalten IEC 60332-1: flammwidrig und selbstverlöschend burning behaviour IEC 60332-1: flame-retardant and self-extinguishing
Normen VDE 7030 Approvals VDE 7030
Du må være logget inn for å se brukerprofiler og sende meldinger.
Logg innAnnonsens metadata
Sist endret: 11.12.2024, 08:22 ・ FINN-kode: 168493293